EasyManuals Logo

Trimble S User Manual

Default Icon
596 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #394 background imageLoading...
Page #394 background image
Chapter 6
Adjustment and verification
Trimble S, VX, SPS & RTS Service Manual6 - 58 P/N 57150002, Revision 5.0
F
9 Verify laser pointer
focus and alignment
on 30 meter.
Aim with instruments
cross-hair to a target,
consisting of encircled
cross lines in 30m
distance.
If the laser pointer is not
aligned with the
instruments cross-hair
then go back to item See
Fig. 6-50 on page 6-57
Transmitter
focus at 30m
target has to be
<15 mm.
If the
transmitter spot
is out of focus
the Transmitter
unit needs to be
replaced.
The spot is not visible
through the
Telescope.
The evaluation of the
transmitter spot,See
Fig. 6-52 on page 6-
58 has to be done
under dark light
condition by close
observation
(alternatively a
theodolite or
binocular can be used
for observation).
Fig. 6-52 Correct focused Laser spot and the generalized spot in 30 m distance
10 Perform a tracker
transmitter alignment
test.
See on page 6-139 .
Item Performance Description Result Notes
<15mm

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trimble S and is the answer not in the manual?

Trimble S Specifications

General IconGeneral
BrandTrimble
ModelS
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals