Chapter 6
Adjustment and verification
Trimble S, VX, SPS & RTS Service Manual6 - 186 P/N 57150002, Revision 5.0
F
Fig. 6-190 TLR transmitter adjustment
8 Check transmitter
divergency.
Verify the laser spot size.
The spare part TLR
module is already
preadjusted, no adjustment
is necessary.
17 intervals ± 3
intervals.
Reading spot size in
the collimator: 17
intervals is 2,5 mrad.
2,5’ in the collimator
is 1,45 mrad.
Fig. 6-191 Deviation TLR laser beam
9 Exit software. Click
Exit.
Item Performance Description Result Notes