User's Manual 278 Document #: LTRT-23510
MP-26x/MP-27x Multimedia Home Gateway
2. The log table displays the following:
Time: to determine the time the event occurred.
Event: type of event. There are five types of events:
Inbound Traffic: The event is a result of an incoming packet.
Outbound Traffic: The event is a result of outgoing packet.
Firewall Setup: Configuration message.
WBM Login: Indicates that a user has logged in to WBM.
CLI Login: Indicates that a user has logged in to CLI (via Telnet).
Event-Type: textual description of the event:
Blocked: The packet was blocked. The message is color-coded red.
Accepted: The packet was accepted. The message is color-coded green.
Details: details of the packet or the event, such as protocol, IP addresses, ports,
etc.
To change the security log settings:
1. In the 'Log' screen, click Settings; the screen 'Log Settings' opens.
Figure 14-30: Security Log Settings

Table of Contents