Parameter Description
interfaces this value is from 1 to 4094.
Click the Apply button to accept the changes made.
The fields that can be configured for Buffer Log Settings are described below:
Parameter Description
Buffer Log State
Select whether the enable or disable the global buffer log state here. Options to
choose from are Enable, Disabled, and Default. When selecting the Default
option, the global buffer log state will follow the default behavior.
Severity
Select the severity value of the type of information that will be logged. Options to
choose from are 0 (Emergencies), 1 (Alerts), 2 (Critical), 3 (Errors), 4
(Warnings), 5 (Notifications), 6 (Informational), and 7 (Debugging).
Discriminator Name
Enter the discriminator name used here. This name can be up to 15 characters
long. This specifies the name of the discriminator profile that will be used to filter
buffer log messages based on the filtering criteria specified within that profile.
Write Delay
Enter the log write delay value here. This value must be between 0 and 65535
seconds. By default, this value is 300 seconds. Tick the Infinite option, to disable
the write delay feature.
Click the Apply button to accept the changes made.
The fields that can be configured for Console Log Settings are described below:
Parameter Description
Console Log State
Select whether the enable or disable the global console log state here.
Severity
Select the severity value of the type of information that will be logged. Options to
choose from are 0 (Emergencies), 1 (Alerts), 2 (Critical), 3 (Errors), 4
(Warnings), 5 (Notifications), 6 (Informational), and 7 (Debugging).
Discriminator Name
Enter the discriminator name used here. This name can be up to 15 characters
long. This specifies the name of the discriminator profile that will be used to filter
console log messages based on the filtering criteria specified within that profile.
Click the Apply button to accept the changes made.
The fields that can be configured for SMTP Log Settings are described below:
Parameter Description
SMTP Log State
Select whether the enable or disable the global SMTP log state here.
Severity
Select the severity value of the type of information that will be logged. Options to
choose from are 0 (Emergencies), 1 (Alerts), 2 (Critical), 3 (Errors), 4
(Warnings), 5 (Notifications), 6 (Informational), and 7 (Debugging).
Discriminator Name
Enter the discriminator name used here. This name can be up to 15 characters
long. This specifies the name of the discriminator profile that will be used to filter
SMTP log messages based on the filtering criteria specified within that profile.
Click the Apply button to accept the changes made.