DGS-3630 Series Layer 3 Stackable Managed Switch Web UI Reference Guide
539
Parameter Description
default value is the PDU priority of the MEP.
Click the Apply button to accept the changes made.
The fields that can be configured in Clear CFM DM are described below:
Parameter Description
Type
Select the type of information to clear here. Options to choose from are:
• Result - Specifies to clear the stored DM results.
• Statistics - Specifies to clear the stored statistics of ETH-DM frames (DMM
and DMR).
Click the Clear button to clear the CFM DM statistics information based on the selection made.
Click the Clear All button to clear all the CFM DM statistics information.
Click the Back button to return to the previous window.
After clicking the Edit LM button, the following page will appear.
Figure 10-11 CFM Settings (Add MA, Add MEP, Edit LM) Window
The fields that can be configured in CFM LM Settings are described below:
Parameter Description
State
Select to enable or disable the ITU Y.1731 Loss Measurement (LM) feature here.
When the administrative state of frame loss measurement function is enabled on
an MEP, the MEP will maintain the counters of frame loss measurement function,
and can reply LMR messages when receiving LMM messages.
Click the Apply button to accept the changes made.
The fields that can be configured in CFM LM Test are described below:

Table of Contents

Other manuals for D-Link DGS-3630 SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the D-Link DGS-3630 SERIES and is the answer not in the manual?

D-Link DGS-3630 SERIES Specifications

General IconGeneral
BrandD-Link
ModelDGS-3630 SERIES
CategorySwitch
LanguageEnglish

Related product manuals