A
B
C
D
E
F
G
H
L
M
N
P
Impianto elettrico
Electric system
sezione / section
P 2
29ST3 - M.Y. 2004 - edizione/edition 00
Check that battery terminals are
properly connected to battery
charger.
To charge battery, proceed as
follows:
Normal charge
(with constant voltage)
Use fast charge for emergencies
only.
Charging the battery under
critical conditions
Flat batteries or batteries left
uncharged for long periods (30 days
max.) must be charged at a constant
current of 0.2-0.5 A for at least
10-12 hours and then slowly charged
- with constant voltage - as described
previously.
Slow
charge
Fast
charge
Constant
voltage (V)
14.4 -14.7 14.4 -14.7
Max.
starting
current (A)
2.5 10
Charging
time (hours)
12 - 24 6 - 8
Ricaricare solo con caricabatterie a
tensione costante.
Usando un caricabatterie di tipo
convenzionale (per auto) si potrebbe
danneggiare la batteria. Assicurarsi
che il collegamento tra i morsetti della
batteria ed il carica batterie sia
corretto.
Per la ricarica seguire le istruzioni di
seguito riportate:
Carica normale
(a tensione costante)
Usare la carica rapida solo in caso di
emergenza
Carica batteria in condizioni
critiche
Nel caso di batterie sottoposte a
scarica profonda o che siano rimaste
scariche per periodi prolungati
(massimo 30 giorni) si consiglia di
caricare la batteria a corrente
costante pari a 0,2 ÷ 0,5 A per almeno
10 ÷ 12 ore, quindi proseguire con la
carica lenta (a tensione costante)
come descritto sopra.
Carica
lenta
Carica
rapida
Tensione
costante (V)
14,4 ÷14,7 14,4 ÷14,7
Corrente ini-
ziale max (A)
2,5 10
Durata della
carica (ore)
12 ÷ 24 6 ÷ 8
R
R
Bk
Y
Y
Y
R
RBkBk
40 A
+
-