EasyManuals Logo

Keysight x-series Programmer's Reference

Keysight x-series
2650 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1186 background imageLoading...
Page #1186 background image
3 VMA Mode
3.8 ACP Measurement
Does not appear in the Swept SA, RTSA, Monitor Spectrum and Complex Spectrum measurements
Appears in the Waveform measurement in BASIC and 5G NR Modes
Preset OFF when Elec Atten is Disabled at preset, otherwise ELEC
State Saved Saved in instrument state
Range
Dual-Attenuator models: Off | Elec Atten Only | Mech + Elec Atten
Single-Attenuator models: Off | On
Backwards Compatibility Command
Notes ON aliases to "Elec Atten Only" (:POW:RANG:OPT:ATT ELEC)
OFF aliases to "Off" (:POW:RANG:OPT:ATT OFF)
:POW:RANG:AUTO? returns true if :POW:RANG:OPT:ATT is not OFF
Backwards
Compatibility
SCPI
[:SENSe]:POWer[:RF]:RANGe:AUTO ON | OFF | 1 | 0
[:SENSe]:POWer[:RF]:RANGe:AUTO?
Adjustment Algorithm
The algorithms for the adjustment are documented below:
Vector Modulation Analyzer Mode User's &Programmer's Reference 1186

Table of Contents

Other manuals for Keysight x-series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight x-series and is the answer not in the manual?

Keysight x-series Specifications

General IconGeneral
Analysis BandwidthUp to 1 GHz (depending on model)
Real-Time BandwidthUp to 1 GHz (depending on model)
Form FactorBenchtop
ConnectivityLAN, USB, GPIB
Resolution Bandwidth1 Hz to 10 MHz (depending on model)