Service Parts Disassembly 8-91
Transfer Unit Belt Rotation Sensor
The Transfer Unit Belt Rotation Sensor is mounted inside the Housing Bias
Assembly.
1. Remove the Housing Bias Assembly.
2. Release 2 hooks that secure the sensor to the assembly.
3. Disconnect the sensor (P/J330) from the harness.
s7400-474
Transfer Unit Belt Rotation Sensor
Housing Bias
Assembly