2-728
Catalyst 4500 Series Switch Cisco IOS Command Reference—Release IOS XE 3.4.0SG and IOS 15.1(2)SG)
OL-27596 -01
Chapter 2 Cisco IOS Commands for the Catalyst 4500 Series Switches
show interfaces transceiver
High Alarm High Warn Low Warn Low Alarm
Current Threshold Threshold Threshold Threshold
Port (milliamperes) (mA) (mA) (mA) (mA)
------- ----------------- ---------- --------- --------- ---------
Gi2/1 50.6 + 60.0 40.0 10.0 5.0
Gi2/2 25.8 60.0 40.0 10.0 5.0
Optical High Alarm High Warn Low Warn Low Alarm
Transmit Power Threshold Threshold Threshold Threshold
Port (dBm) (dBm) (dBm) (dBm) (dBm)
------- ----------------- ---------- --------- --------- ---------
Gi2/1 -16.7 (-13.0) -- 3.4 3.2 -0.3 -0.5
Gi2/2 0.8 ( 5.1) 3.4 3.2 -0.3 -0.5
Optical High Alarm High Warn Low Warn Low Alarm
Receive Power Threshold Threshold Threshold Threshold
Port (dBm) (dBm) (dBm) (dBm) (dBm)
------- ----------------- ---------- --------- --------- ---------
Gi2/1 N/A (-28.5) 5.9 -6.7 -28.5 -28.5
Gi2/2 N/A (-19.5) 5.9 -6.7 -28.5 -28.5
Switch#
This example shows how to display the monitoring data for the transceivers on interface Gi1/2:
Switch# show interfaces g1/2 transceiver
ITU Channel 23 (1558.98 nm),
Transceiver is externally calibrated.
If device is externally calibrated, only calibrated values are printed.
++ : high alarm, + : high warning, - : low warning, -- : low alarm.
NA or N/A: not applicable, Tx: transmit, Rx: receive.
mA: milliamperes, dBm: decibels (milliwatts).
Optical Optical
Temperature Voltage Current Tx Power Rx Power
Port (Celsius) (Volts) (mA) (dBm) (dBm)
------- ----------- ------- -------- -------- --------
Gi2/1 43.7 5.03 50.6 + -16.7 -- N/A
Switch#
This example shows how to display detailed the monitoring data for the transceivers on interface Gi1/2:
Switch# show interfaces g1/2 transceiver detail
ITU Channel 23 (1558.98 nm),
Transceiver is externally calibrated.
mA: milliamperes, dBm: decibels (milliwatts), NA or N/A: not applicable.
++ : high alarm, + : high warning, - : low warning, -- : low alarm.
A2D readouts (if they differ), are reported in parentheses.
The threshold values are calibrated.
High Alarm High Warn Low Warn Low Alarm
Temperature Threshold Threshold Threshold Threshold
Port (Celsius) (Celsius) (Celsius) (Celsius) (Celsius)
------- ------------------ ---------- --------- --------- ---------
Gi2/1 43.5 70.0 60.0 5.0 0.0
High Alarm High Warn Low Warn Low Alarm
Voltage Threshold Threshold Threshold Threshold
Port (Volts) (Volts) (Volts) (Volts) (Volts)
------- --------------- ---------- --------- --------- ---------
Gi2/1 5.03 5.50 5.25 4.75 4.50