EZ-USB FX3 Technical Reference Manual, Document Number: 001-76074 Rev. *F 307
GPIF_AD_CONFIG
0xE001400C
10.7.4 GPIF_AD_CONFIG (continued)
7:6 AOUT_SELECT[1:0] 0 Connect AOUT to ADDR_COUNTER
1 Connect AOUT to EGRESS_ADDRESS register
2 Connect AOUT to the socket pointed to by ADDRESS_THREAD register
5:4 AIN_SELECT[1:0] 0 Connect AIN to the active socket number of thread specified by AIN_DATA
1 Connect AIN to INGRESS_ADDRESS register
2 Connect AIN to the socket pointed to by ADDRESS_THREAD register
3:2 A_OEN_CFG[1:0] Address lines (if there are any) are
0 Always outputs
1 Always inputs
2 Controlled by the beta: “a_oen”
3 Reserved
1:0 DQ_OEN_CFG[1:0] Data lines are
0 Always outputs
1 Always inputs
2 Direction controlled by the alpha: “dq_oen”
3 Reserved
Note that CTRL[2] can be OE, controlling the data output drivers directly, overriding what's specified
here (this field should be set to 0 if that is used)