EZ-USB FX3 Technical Reference Manual, Document Number: 001-76074 Rev. *F 537
I2S_COUNTER
0xE0000018
10.18.7 I2S_COUNTER
I2S Sample Counter Register
Counts number of samples written to output (L+R counts as one), can be used in software PLL to control audio decode
thread.
31:0 COUNTER[31:0] Counter increments by one for every sample written on output. Counts L+R as one sample in stereo
mode. This counter is more reliable to implement a software PLL because of more periodic behavior.
This counter will be reset to 0 when I2S_CONFIG.ENABLE=0.
I2S_COUNTER I2S Sample Counter Register 0xE0000018
b31 b30 b29 b28 b27 b26 b25 b24
COUNTER[31:24]
RRRRRRRR
R/W R/W R/W R/W R/W R/W R/W R/W
00000000
I2S_COUNTER I2S Sample Counter Register
b23 b22 b21 b20 b19 b18 b17 b16
COUNTER[23:16]
RRRRRRRR
R/W R/W R/W R/W R/W R/W R/W R/W
00000000
I2S_COUNTER I2S Sample Counter Register
b15 b14 b13 b12 b11 b10 b9 b8
COUNTER[15:8]
RRRRRRRR
R/W R/W R/W R/W R/W R/W R/W R/W
00000000
I2S_COUNTER I2S Sample Counter Register
b7 b6 b5 b4 b3 b2 b1 b0
COUNTER[7:0]
RRRRRRRR
R/W R/W R/W R/W R/W R/W R/W R/W
00000000
Bit Name Description