EZ-USB FX3 Technical Reference Manual, Document Number: 001-76074 Rev. *F 417
OTG_TIMER
0xE0031818
10.12.7 OTG_TIMER
OTG Timer Register
General timer register to create OTG timeouts. This counter decrements down at 32-kHz standby clock.
31:0 OTG_TIMER_LOAD_VAL[31:0] Initial counter value. After OTG_TIMER_LOAD_VAL clocks, OTG_TIMER_TIMEOUT will
trigger. Disable counter by writing 0 to this register.
OTG_TIMER OTG Timer Register 0xE0031818
b31 b30 b29 b28 b27 b26 b25 b24
OTG_TIMER_LOAD_VAL[31:24]
R/W R/W R/W R/W R/W R/W R/W R/W
RRRRRRRR
00000000
OTG_TIMER OTG Timer Register
b23 b22 b21 b20 b19 b18 b17 b16
OTG_TIMER_LOAD_VAL[23:16]
R/W R/W R/W R/W R/W R/W R/W R/W
RRRRRRRR
00000000
OTG_TIMER OTG Timer Register
b15 b14 b13 b12 b11 b10 b9 b8
OTG_TIMER_LOAD_VAL[15:8]
R/W R/W R/W R/W R/W R/W R/W R/W
RRRRRRRR
00000000
OTG_TIMER OTG Timer Register
b7 b6 b5 b4 b3 b2 b1 b0
OTG_TIMER_LOAD_VAL[7:0]
R/W R/W R/W R/W R/W R/W R/W R/W
RRRRRRRR
00000000
Bit Name Description