EZ-USB FX3 Technical Reference Manual, Document Number: 001-76074 Rev. *F 481
LNK_ERROR_COUNT
0xE0033014
10.15.6 LNK_ERROR_COUNT
Error Counter Register
Error counter register keeps track of errors from PHY and Link Controller. Only errors enabled in LNK_PHY_ERROR_CONF
and LNK_LINK_ERROR_CONF are counted.
31:16 PHY_ERROR_COUNT[15:0] Count of receive errors from the USB 3.0 PHY. This is for debug purposes.
15:0 LINK_ERROR_COUNT[15:0] The Link Error Count keeps track of the number of errors for which the Link Layer Block had
to transition to the Recovery State before resuming normal operation. Counting of errors in
each class can be enabled through the LINK_ERROR_CONF register.
LNK_ERROR_COUNT Error Counter Register 0xE0033014
b31 b30 b29 b28 b27 b26 b25 b24
PHY_ERROR_COUNT[15:8]
R/W R/W R/W R/W R/W R/W R/W R/W
R/W R/W R/W R/W R/W R/W R/W R/W
00000000
LNK_ERROR_COUNT Error Counter Register
b23 b22 b21 b20 b19 b18 b17 b16
PHY_ERROR_COUNT[7:0]
R/W R/W R/W R/W R/W R/W R/W R/W
R/W R/W R/W R/W R/W R/W R/W R/W
00000000
LNK_ERROR_COUNT Error Counter Register
b15 b14 b13 b12 b11 b10 b9 b8
LINK_ERROR_COUNT[15:8]
R/W R/W R/W R/W R/W R/W R/W R/W
R/W R/W R/W R/W R/W R/W R/W R/W
00000000
LNK_ERROR_COUNT Error Counter Register
b7 b6 b5 b4 b3 b2 b1 b0
LINK_ERROR_COUNT[7:0]
R/W R/W R/W R/W R/W R/W R/W R/W
R/W R/W R/W R/W R/W R/W R/W R/W
00000000
Bit Name Description

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cypress EZ-USB FX3 and is the answer not in the manual?

Cypress EZ-USB FX3 Specifications

General IconGeneral
BrandCypress
ModelEZ-USB FX3
CategoryController
LanguageEnglish

Related product manuals