GBC AdvancedPunch Pro 08/20/2015 Repairs/Adjustments
4-17
REP 1.16 LCD Membrane Switch Panel Replacement
PARTS LIST ON PL 2.2
Use this procedure to remove and install the LCD Membrane Switch
Panel.
WARNING
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
1. Switch power OFF to entire printing system.
2. Disconnect the Power Cord.
3. Open the Front Door.
4. Disconnect the LCD Membrane Switch Connector from the LCD
Display.
5. Remove the M4 nut that secures the strap to the Top cover.
6. Peel off the old LCD Membrane Switch.
Installation Procedure
1. Install the new Membrane within the indent of the Top Cover.
2. Close the Front Door.
3. Connect the LCD Membrane Switch Connector from the LCD Display.
4. Connect the Power Cord.
5. Power ON the entire printing system.