GBC AdvancedPunch Pro - Rap 4.3; Check Solenoids SOL 3 to SOL 8

GBC AdvancedPunch Pro
400 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GBC AdvancedPunch Pro 11/07/2018 RAPS
2-44
RAP 4.3 Check Solenoids SOL 3 to SOL 8
Use this RAP to check Solenoids SOL3, SOL4, SOL5, SOL6, SOL7, and
SOL8.
1. Open the front the door and insert an Interlock Cheater into the
Punch Door interlock Switch SW4 (PL 2.2).
WARNING
Moving Parts, keep hands clear of nips and the belts when
the Interlock Cheater is inserted. See Section 0, page vii
for other languages.
2. Do GP 6.2.10 SOLENOIDS Procedure to activate and deactivate the
affected solenoid.
When the solenoid is not activated, the idler roller should be able to
rotate freely, and in turn drive the drive roller.
not activated fully activated
When the solenoid is fully activated, the idler roller should completely
lift off and not be able to drive the drive roller.
NOTE: Disengaging solenoid modules need to be replaced every 5
million cycles.
To check the holding force of the solenoid, go to Step 3
If the solenoid does not actuate, go to Step 4
Alternate solenoid inspection method:
Mark a line on the idler roller shaft as shown in the picture.
Motor running + Solenoid actuated = Line not visible
Motor running + Solenoid not actuatuated = Line visible
Picture shows Motor running and solenoid actuated.
From the service mode solenoid can be actuated using GP 6.2.10
Solenoids Procedure, and the corresponding drive roller rotated
manually to check this.