GBC AdvancedPunch Pro 09/11/2018 General Procedures and Information
6-77
GP 6.25 Diverter Solenoid Assembly Inspection
Use this procedure to inspect the Diverter Solenoid Assembly every
1000K cycles.
1. Press the Power Switch to the off position.
2. Disconnect the Power Cord.
3. Do REP 1.6 to remove the Rear Cover.
4. Clean the Solenoid and surrounding area with a vacuum cleaner and
canned air.
5. Make sure the solenoid is clean and dry.
6. Raise the Diverter Solenoid by hand and release it. The Diverter
should fall freely. Make sure the linkage operates smoothly.
7. Open the front door and insert an Interlock Cheater into the Punch
Door Interlock switch SW4 (PL2.2).
8. Press the Power Switch to the on position.
Warning
Moving Parts, keep hands clear of nips and the belts when the
Interlock is cheater is inserted. See Section 0, page vii for other
languages.
9. Do GP 6.2.10 Solenoids Procedure to activate and deactivate
Solenoid SOL1.
The diverter gate should rise and fall when SOL1 is cycled.
GP 6.26 Die Set Recognition Board Clips Inspection
Use this procedure to Inspect and clean the Die Set recognition board
clips every 1000K cycles.
1. Press the Power Switch to the off position.
2. Disconnect the Power Cord.
3. Do REP 1.6 to remove the Rear Cover.
4. Inspect the Die Set Recognition reader spring clips to check if they
are bent. When a die set is inserted, the spring clips should deform
and fully contact the Die Set Recognition Board in the Die Set .
5. Wipe the spring clips with a clean cloth.
6. Do ADJ 1.6 if necessary.