2 - 50 Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4 Electra Elite IPK
Display (R3000 or higher)
Notes
Programming Procedures
1 Go off-line.
2 Press LK1 + LK1
+
CG
to access the Memory Block.
3 Use the dial pad to enter the Data Setting for Class 1.
Setting Data
00s~99s (e.g., 02s = 2s)
Default Values
Class 1~4 = 10s
00s = No Limit
4 Press G to write the data and display the next Timer Class of Service.
5 Program the next Timer Class of Service or press
E to go back on-line.
Related Programming
M.B. Number Memory Block Name
4-71
Station to Timer Class of Service (R3000 or higher)
1. When all trunks in a particular Trunk group are busy, the station user can dial an Access Code to queue on the
busy Trunk group. When a Trunk in that group becomes idle, the queued station is signaled.
2. Telephone ports 1 and 2 are in Station to Timer Class of Service, Class 1 by default. All other ports are in Station
to Timer Class of Service, Class 2 by default
(R3000 or higher).
3. When a system is upgraded from R2500 or lower to
R3000 or higher, the Trunk Queuing Timeout Selection is
reset to the default value during the upgrade process
.