2 - 78 Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4 Electra Elite IPK
1-1-60 8-Digit Matching Table Assignment
General Description
Use this Memory Block to assign the outgoing dial digit for Code Restriction (except
OCC Dial Digit - Normal Dial). Program this assignment in one of two ways:
a) When the user dials digit(s) and there is a match, the system allows free dialing or
denies dialing by disconnecting. Refer to Memory Block 1-1-61 (8-Digit Matching
Table to Class Assignment) for programming.
b) When a user dials digit(s) and there is no match, the system allows free dialing or
denies dialing by disconnecting. Refer to Memory Block 1-1-65 (Code Restriction
Class Allow/Deny Selection) for programming.
Display
Programming Procedures
1 Go off-line.
2 Press LK1 + LK1 +
FK
to access the Memory Block.
3 Use the dial pad to enter the data for Dial Code 00 for 8-Digit Matching Table 00.
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
~
I
to enter numeric data
H to clear data
The information that can be entered includes:
Matching Table: 00~15 (8-digit)
Dial Code: 00~15
Dial Digit: 0~9,
,
, #, NANP = X, P, N (Maximum eight digits)
System Mode
1
Submode
1
Data No.
60
PC Programming
¦
+AC
6 0 : 8 D I G I T T A B L E
0 0 / 0 0 = 9 1 1
Title
Data
No.
8-Digit
Matching
Table
Dial
Code
Dial Digit
(max . 8)