Electra Elite IPK Document Revision 4
Programming Manual 2 - 407
___________________________________________________________________________________
___________________________________________________________________________________
1-16-14 Port VLAN Group Membership
General Description
Use this Memory Block to create a list of accepted VLANs for each port. When
Memory Block 1-16-04 (VLAN Mode Selection) is set to YS, each port accepts
frames tagged with VLAN IDs only when the port is programmed as a member of that
VLAN Group. Frames without VLAN tags are also permitted. When Port Mirroring is
used, the source and target ports must be members of the same VLAN(s).
R1500 or higher is required.
Display
Settings
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8 The shaded
selection is the
default.
NO YS
Programming Procedures
1 Go off-line.
2 Press LK1 + LK16 +
JJAD
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the option.
4 Press
G to write the data.
5 Repeat steps 3 and 4 for each HUB(8)-U( ) ETU and VLAN Group.
6 Press
E to go back on-line.
System Mode
1
Submode
16
Data No.
14
PC Programming
¦
+AB
1 4 : 1 P O R T 0 1 = 1 N O
T I M E D I S P L A Y
Data
No.
Setting
Data
Title
VLAN Gp
01~16
HUB
1~3
Port
1~8