7-3-01 MIF (LCR) Assignment
General Description
Use this Memory Block to enable the Least Cost Routing (LCR) function of the
MIFM-U10/20 ETU and the SPE(M)-U( ) ETU.
Display
Notes
Programming Procedures
1 Go off-line.
2 Press LK7 + LK3 +
JA
to access the Memory Block.
3 Use the dial pad to enter data.
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
~
I
to enter numeric data
Setting Data: 00, 01, 02
Default Value
No Assignment (00)
4 Press G to write the data.
5 Press
E to go back on-line.
1. The LCR feature requires a KMM(1.0)U to be installed on the MIFM-U10 ETU.
2. The LCR feature requires a KMM-U20 to be installed on the MIFM-U20 ETU.
ETU Mode
7
MIF
3
Data No.
01
PC Programming
¦
+BS
0 1 : L C R M I F = 0 0
T I M E D I S P L A Y
Data
No.
Title
Setting
Data