Electra Elite IPK Document Revision 4
Programming Manual 2 - 441
___________________________________________________________________________________
___________________________________________________________________________________
3-17 Tie Line Answer Detect Time
Selection
General Description
Use this Memory Block to specify the time before an Electra Elite IPK system answer
(off-hook) is recognized as an answer.
Display
Settings
Page 1
Notes
LK 1LK 2LK 3LK 4LK 5LK 6LK 7LK 8
The shaded
selection is the
default. Times
are in
milliseconds.
0 130 260 390 520 650 780 910
Page 2
LK 1LK 2LK 3LK 4LK 5LK 6LK 7LK 8
1040 1170 1300 1430 1560 1690 1820 1950
Programming Procedures
1 Go off-line.
2 Press LK3 +
G +
AG
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change answer detect time for CO/PBX No.
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
~
I
to enter numeric data or CO/PBX No.
– OR –
D to go to the next assigned CO/PBX No.
C to go to the next page
A to go to the previous page
4 Press
G to write the data and display the next Memory Block.
5 Program the next Memory Block or press
E to go back on-line.
1. Answering a call may be impossible if the CO answer detect time is too long.
2. This Memory Block affects T1 channels assigned as Tie/DID lines.
CO/PBX Line Mod