Loading...
2 - 80 Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4 Electra Elite IPK
1-1-61 8-Digit Matching Table to Class
Assignment
General Description
Use this Memory Block to program each 8-digit Matching Table to allow or deny
assignment per class. Classes 00 and 15 are fixed. Only classes 01
~14 can be
programmed.
Display
Settings
Related Programming.
Refer to Chapter 3 Advanced Applications, Section 1 Code Restriction on page 3-1.
LK 1 LK 2LK 3LK 4LK 5LK 6LK 7LK 8
The shaded
selection is the
default.
NON
YS
(Allow)
NO
(Deny)
Programming Procedures
1 Go off-line.
2 Press LK1 + LK1 +
FA
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option for Class 01 Table 00.
Classes:
Class 00 and 15 cannot be programmed
Class 00 has no restrictions (Allow)
Class 15 has restricted outgoing (Deny)
Refer to the table on the next page.
4 Press
G to write the data and advance to the next Table and then to the next Class. Repeat Steps 3 and 4 for each Class
and Table.
5 After data for the last Table for the last Class is entered, the next Memory Block is displayed.
6 Program the next Memory Block or press
E to go back on-line.
System Mode
1
Submode
1
Data No.
61
PC Programming
¦
+AC
Data
No
6 1 : C L S 0 1 ( 0 0 ) = Y S
T I M E D I S P L A Y
Class
No.
01~14
Table
00~15
Title
Setting
Data