4-94 3-Minute Alarm Selection
General Description
Use this Memory Block to specify per station whether or not a warning tone is
generated at 3-minute intervals during an outgoing or incoming CO/PBX call.
Display
Settings
Notes
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8 The shaded
selection is the
default.
NO YS
Programming Procedures
1 Go off-line.
2 Press LK4 +
ID
to access the Memory Block.
3 Press LK2 to generate a three-minute warning tone during a call for Tel port No.
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
~
I
to enter numeric data or Tel Port No.
OR –
D to go to next assigned Tel Port No.
B +
A
to enter A for Port Numbers 100~109
B +
B
to enter B for Port Numbers 110~119
B +
C
to enter C for Port Number 120
4 Press
G to write the data and display the next Memory Block.
5 Program the next Memory Block or press
E to go back on-line.
1. A 1-second (approximately) warning signal sounds every three minutes during CO/PBX calls.
2. The alarm tone is heard through the terminal speaker only.
3. When the built-in speakerphone is used for handsfree, the warning signal is not used.
4. Telephone ports A0~C0 are ports 100~120.
Telephone Mode
4
Submode
Data No.
94
PC Programming
¦
+BTM
Data
No.
0 1 / 9 4 : 3 m A L M N O
T I M E D I S P L A Y
Tel
Port
No.
(01
~
C0)
Title
Setting
Data