EasyManua.ls Logo

NEC Electra Elite IPK - PBR Receive Level Assignment for Automated Attendant;Disa

NEC Electra Elite IPK
803 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 - 208 Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4 Electra Elite IPK
1-8-02 PBR Receive Level Assignment for
Automated Attendant/DISA
General Description
Use this Memory Block to specify the receiving level of the Push Button Receiver
(PBR) at the Automated Attendant/Direct Inward System Access (DISA).
Display
1 Go off-line.
2 Press LK1 + LK8 +
KB
to access the Memory Block.
3 Use the dial pad to change the data option. The information that can be entered
includes:
Setting Data Receiving Level
00 -33.0 dBm
01 -34.0 dBm
02 -35.0 dBm
03 -36.0 dBm
04 -37.0 dBm
05 -38.0 dBm
06 -39.0 dBm
07 -40.0 dBm
08 -41.0 dBm
09 -42.0 dBm
10 -43.0 dBm
11 -44.0 dBm
12 -45.0 dBm
13 -46.0 dBm
14 -47.0 dBm
15 -48.0 dBm
4 Press
G to write the data and advance to the next PBR.
5 Enter next PBR, and press
G to write data. The next Memory Block is displayed.
6 Program the next Memory Block or press
E to go back on-line.
System Mode
1
Submode
8
Data No.
02
PC Programming
¦
+AU
0 2 : P B R 1 = 0 3
T I M E D I S P L A Y
Title
Data
No.
PBR
No.
1/2
Setting
Data
Default Values
(PBR 1 and 2)
Setting
Data
Receiving
Level
03 -36.0 dBm

Table of Contents