A - 6 Function Time Chart
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4 Electra Elite IPK
ACD/UCD Overflow
Time Selection
1-12-02 The maximum time (seconds) a
waiting ACD/UCD call remains
at an ACD/UCD group before
overflowing to a specified
Station or Station Hunt group.
10 60
∞
Centralized BLF
Send Time
Assignment
1-15-17 The time (seconds) for sending
BLF information across the
K-CCIS Network.
4416
Trunk DTMF
Duration/Interdigit
Selection
3-15 The tone duration/interdigit
time (milliseconds) of DTMF
signals.
60/70 110/80 810/190
Tie Line Prepause
Time Selection
3-16 The prepause time (seconds)
when the originating side can
send dial pulse or DTMF to a
distant system.
0 0 13.0
Tie Line Answer
Detect Time
Selection
3-17 The time (milliseconds)
between when the receiving
system answers and the time
when it is recognized as an
answer.
0 520 1950
Tie Line Release
Detect Time
Selection
3-18 The time (milliseconds)
between when the circuit
disconnection is detected on
the Tie line on the distant
system side and when it is
recognized as Tie Line
Release.
0 520 1950
Tie Line/CO/PBX
Incoming Signal
Detect Time
Selection
3-19 The time (milliseconds)
between when an incoming
signal is detected from another
Electra Elite system and the
acknowledgment signal is sent
(Expressed as Wink Start/
Delay/COI).
0/0/50
00 (LK 1)
390/90/200
03 (LK 4)
1950/450/
800
15 (LK 8)
Tie Line Loop
Off-Guard Time
Selection
3-20 Off-guard time (seconds) to
prevent noise that may cause
the system to be unable to
answer an incoming Tie line.
0.0 2.0 13.0
Tie Line Length of
Wink Signal
Selection
3-21 The time (milliseconds) of a
Wink pulse that is sent to
another Electra Elite system.
30 180 480
Table A-1 Function Time Chart (Continued)
Time
Memory
Block
Definition
Value
Minimum Default Maximum