2 - 122 Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4 Electra Elite IPK
1-2-22 Call Forward - No Answer Time
Selection
General Description
Use this Memory Block to specify the time before incoming intercom calls or incoming
CO/PBX lines are forwarded to another station number when the called party does not
answer.
This Memory Block can be adjusted in 1-second intervals (R3000 or higher).
Display (R2500 or lower)
Settings
Refer to next page for R3000 or higher Programming Procedures.
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8 The shaded
selection is the
default.
4s 8s 12s 18s 24s 30s 60s
Programming Procedures
1 Go off-line.
2 Press LK1 + LK2 +
BB
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option.
4 Press
G to write the data and display the next Memory Block.
5 Program the next Memory Block or press
E to go back on-line.
System Mode
1
Submode
2
Data No.
22
PC Programming
¦
+BM
2 2 : F W D N O A N S 8 s
T I M E D I S P L A Y
Setting
Data
Title
Data
No.