2 - 436 Memory Blocks
___________________________________________________________________________________
Document Revision 4 Electra Elite IPK
___________________________________________________________________________________
3-14 Tie Line Type Assignment
General Description
Use this Memory Block to assign the loop supervision to be used for each Trunk
associated with a Tie line.
Display
Settings
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8 The shaded
selection is the
default.
2ND DIAL IMMEDIATE DELAY WINK
Programming Procedures
1 Go off-line.
2 Press LK3 +
G +
AD
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the loop supervision for CO/PBX No.
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
~
I
to enter numeric data or CO/PBX No.
– OR –
D to go to the next assigned CO/PBX No.
4 Press
G to write the data and display the next Memory Block.
5 Program the next Memory Block or press
E to go back on-line.
Related Programming
M.B. Number Memory Block Name
3-92
Trunk (Installed, DP/DTMF) Selection
CO/PBX Line Mod
e
3
Submode
Data No.
14
PC Programming
¦
+ALT
0 1 / 1 4 : 2 N D D I A L
T I M E D I S P L A Y
Tie/DID
No.
(01~64)
Data
No.
Title