Electra Elite IPK Document Revision 4
Programming Manual 2 - 467
___________________________________________________________________________________
___________________________________________________________________________________
3-33 Disconnect Recognition Time
Selection
General Description
Use this Memory Block to specify the minimum time before a disconnected circuit can
be accessed again.
Display
Settings
Page 1
Notes
LK 1LK 2LK 3LK 4LK 5LK 6LK 7LK 8
The shaded
selection is the
default. Times
are in seconds.
00.10.20.3 0.4 0.5 0.6 0.7
Page 2
LK 1LK 2LK 3LK 4LK 5LK 6LK 7LK 8
0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5
Programming Procedures
1 Go off-line.
2 Press LK3 +
G +
CC
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change disconnect recognition time for CO/PBX No.
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
~
I
to enter numeric data or CO/PBX No.
– OR –
D to go to the next assigned CO/PBX No.
C to go to the next page
A to go to the previous page
4 Press
G to write the data and display the next Memory Block.
5 Program the next Memory Block or press
E to go back on-line.
When a call origination on a CO/PBX line or Tie line is interrupted or dropped, and an attempt is made to seize
the line again, it must be disconnected and cleared before it can be accessed again.
CO/PBX Line Mod