EasyManua.ls Logo

NEC Electra Elite IPK - First Delay Announcement Start Time Selection; First Delay Announcement Repeat Selection

NEC Electra Elite IPK
803 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electra Elite IPK Document Revision 4
Programming Manual 2 - 91
___________________________________________________________________________________
___________________________________________________________________________________
1-1-71 First Delay Announcement Start Time
Selection
General Description
Use this Memory Block to specify the time between receiving a CO call and sending a
First Delay Announcement to the calling party.
Display
Settings
Notes
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8 The shaded
selection is the
default. Times
are in seconds.
00 10 20 30 40 50 60
Programming Procedures
1 Go off-line.
2 Press LK1 + LK1 +
GA
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option.
4 Press
G to write the data and display the next Memory Block.
5 Program the next Memory Block or press
E to go back on-line.
Related Programming
M.B. Number Memory Block Name
1-1-72
First Delay Announcement Repeat Selection
1-8-13
VRS Message Function Assignment
3-41
Delay Announcement Assignment
This Memory Block does not display unless the MIFA-U ( ) ETU is installed.
System Mode
1
Submode
1
Data No.
71
PC Programming
¦
+AR
7 1 : M S G S T A R T = 2 0
T I M E D I S P L A Y
Data
No.
Title
Setting
Data

Table of Contents