4-02 CO/PBX Ring Assignment
(Night Mode)
General Description
Use this Memory Block to assign incoming CO/PBX calls to ring in Night Mode.
Display
Settings
1
Settings 2
Page 1 – Trunks 01~08
Tel Port
Number
Meaning Operation
*A0~A9 100~109 B + 1 for A
*B0~B9 110~119 B + 2 for B
*C0 120 B + 3 for C
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8
The shaded
selection is the
default.
01 02 03 04 05 06 07 08
Page 2 – Trunks 09~16
LK 1LK 2LK 3LK 4LK 5LK 6LK 7LK 8
09 10 11 12 13 14 15 16
Page 3 – Trunks 17~24
LK 1LK 2LK 3LK 4LK 5LK 6LK 7LK 8
17 18 19 20 21 22 23 24
Page 4 – Trunks 25~32)
LK 1LK 2LK 3LK 4LK 5LK 6LK 7LK 8
25 26 27 28 29 30 31 32
Page 5 – Trunks 33~40
LK 1LK 2LK 3LK 4LK 5LK 6LK 7LK 8
33 34 35 36 37 38 39 40
Telephone Mode
4
Submode
Data No.
02
PC Programming
¦
+BTT
Data
No.
0 1 / 0 2 : R N G N T | 0 1
T I M E D I S P L A Y
Tel
Port
No.
(01
~
C0)
*
Title
Trunk
No.

Table of Contents