Notes
Page 7 – Trunks 49~56
LK 1LK 2LK 3LK 4LK 5LK 6LK 7LK 8
49 50 51 52 53 54 55 56
Page 8 – Trunks 57~64
LK 1LK 2LK 3LK 4LK 5LK 6LK 7LK 8
57 58 59 60 61 62 63 64
Programming Procedures
1 Go off-line.
2 Press LK4 to access the Memory Block.
3 Press the CO/PBX Line key to select Day ring assignment for Tel Port No.
The LED indication changes to indicate data each time a CO/PBX line key is pressed.
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
~
I
to enter numeric data or Tel Port No.
– OR
D to go to next assigned Tel Port No.
C to go to the next page
A to go to the previous page
Default Values
CO/PBX lines 01 ~ 08 ring at Tel Port
numbers 01 and 02.
Tel Port numbers 03 ~ 120 do not ring
on any incoming CO/PBX calls.
4 Press G to write the data and display Memory Block 4-02.
5 After programming Memory Blocks 4-02~4-59, the next sequential Tel Port No. is automatically displayed.
6 Repeat steps 3, 4, and 5 until all Tel Port Nos. are programmed. Tel Port No. 01 is displayed again.
7 Press
E to go back on-line.
Telephone ports A0~C0 are ports 100~120. Refer to Settings 1 to enter ports A0~C0.