2 - 110 Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4 Electra Elite IPK
1-2-03 2~7-Digit Station Number Selection
General Description
Use this Memory Block to determine the number of digits for station numbers. Either
2-digit (10~89), 3-digit (100~899), or 4-digit (1000~8999) assignment is available or a
5-, 6-, or 7-digit station numbering plan is available.
System Software R2500 is required to assign 5-, 6-, or 7-Digit station numbering
plan.
Display
Settings
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8 The shaded
selection is the
default.
2DGT 3DGT 4DGT 5DGT 6DGT 7DGT
Programming Procedures
1 Go off-line.
2 Press LK1 + LK2 +
KC
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option.
4 Press
G to write the data and display the next Memory Block.
5 Program the next Memory Block or press
E to go back on-line.
Related Programming
M.B. Number Memory Block Name
1-1-46
Access Code (1-Digit) Assignment
1-1-47
Access Code (2-Digit) Assignment
1-1-48
Access Code (3-Digit) Assignment
1-2-34
Expanded Station Number Assignment
1-8-26
Voice Mail Quick Transfer Master Hunt Number
4-10
Station Number Assignment
System Mode
1
Submode
2
Data No.
03
PC Programming
¦
+BS
0 3 : S T A . N O . 3 D G T
T I M E D I S P L A Y
Setting
Data
Title
Data
No.