2 - 4 Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4 Electra Elite IPK
1-1-02 Hookflash Time Selection
General Description
Use this Memory Block to specify the loop open time for a hookflash signal sent to the
CO or PBX when the Recall key on a Multiline Terminal is pressed. A Single Line
Telephone (SLT) generates a hookflash to the CO or PBX line when a Single Line
Telephone hookflash is assigned.
Display
Settings
Page 1
LK 1LK 2LK 3LK 4LK 5LK 6LK 7LK 8
The shaded
selection is the
default.
20ms 40ms 60ms 80ms 100ms 140ms 160ms 200ms
Page 2
LK 1 LK 2LK 3LK 4LK 5LK 6LK 7LK 8
400ms 600ms 800ms 1.0s 1.5s 2.0s 3.0s 5.0s
Programming Procedures
1 Go off-line.
2 Press LK1 + LK1
+
KB
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option.
Use the following to enter data:
C to go to the next page
A to go to the previous page
4
Press
G
to write the data and display the next Memory Block.
5 Program the next Memory Block or press E to go back on-line.
System Mode
1
Submode
1
Data No.
02
PC Programming
¦
+BCM