1-4-08 Automated Attendant PBR Timeout
Response Selection
General Description
Use this Memory Block to specify how a call answered by the Automated Attendant
should be processed when a dual-tone multifrequency (DTMF) tone is not received.
Display
Settings
Related Programming
Refer to individual features in the Electra Elite IPK Features and Specifications Manual.
Notes
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8 The shaded
selection is the
default.
NORMAL RELEAS
Programming Procedures
1 Go off-line.
2 Press LK1 + LK4 +
JH
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option.
4 Press
G to write the data and display the next Memory Block.
5 Program the next Memory Block or press
E to go back on-line.
1. When NORMAL is selected, and a DTMF tone is not received during the Automated Attendant message or
during the Automated Attendant Push Button Receiver (PBR) Release Time (20-second default), the system
rings selected stations using Memory Block 4-01 [CO/PBX Ring Assignment (Day Mode)] or Memory Block 4-02
[CO/PBX Ring Assignment (Night Mode)].
2. When RELEAS is selected, and a DTMF tone is not received during the Automated Attendant message or during
the Automated Attendant PBR Release Time (20-second default), the system drops the call after 30 seconds
regulated by a fixed time.
System Mode
1
Submode
4
Data No.
08
PC Programming
¦
+AU
0 8 : A A R E S N O R M A L
T I M E D I S P L A Y
Setting
Data
Title
Data
No.