2 - 138 Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4 Electra Elite IPK
1-3-02 SLT Hookflash Signal Selection
General Description
Use this Memory Block to specify whether a line is held internally, or when behind a
PBX, a hookflash (HF) signal is sent to the line when a Single Line Telephone user
performs a hookflash.
Display
Settings
Notes
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8 The shaded
selection is the
default.
HOLD FLASH
Programming Procedures
1 Go off-line.
2 Press LK1 + LK3
+
KB
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option.
4 Press
G to write the data and display the next Memory Block.
5 Program the next Memory Block or press
E to go back on-line.
Related Programming
M.B. Number Memory Block Name
1-1-02
Hookflash Time Selection
4-24
SLT Hookflash Assignment
1. When Hold is specified, the CO/PBX line is put on Exclusive Hold.
2. When Hold is selected, the PBX/CTX line can receive the hookflash signal using Access Code 6# (default).
3. When Flash is specified, press the hookswitch to send the hookflash signal to the PBX/CTX line.
System Mode
1
Submode
3
Data No.
02
PC Programming
¦
+BTI