2 - 350 Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4 Electra Elite IPK
1-15-08 Link Reconnect Allow/Deny Selection
General Description
Use this Memory Block to allow or deny the Link Reconnect feature.
Display
Settings
LK 1 LK 2LK 3LK 4LK 5LK 6LK 7LK 8
The shaded
selection is the
default.
NO
(Deny)
YS
(Allow)
Programming Procedures
1 Go off-line.
2 Press LK1 + LK15 +
KH
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the option.
4 Press
G to write the data.
5 Press
E to go back on-line.
Related Programming
M.B. Number Memory Block Name
7-1
Card Interface Slot Assignment
7-3-01
MIF (LCR) Assignment
7-3-02
MIF (SMDR) Assignment
1-15-00
K-CCIS Main/Remote Office Selection
1-15-01
Common Signal Channel Data Speed Assignment
1-15-02
Common Signal Channel Assignment
1-15-03
Originating Point Code Assignment
1-15-04
Destination Point Code Assignment
1-15-05
Destination Point Code Transfer Assignment
1-15-06
Originating Office Code Number Assignment
1-15-07
K-CCIS Message Response Timeout Assignment
1-15-09
K-CCIS Maximum Call Forwarding Hop Assignment
System Mode
1
Submode
15
Data No.
08
PC Programming
¦
+AW
0 8 : R E C O N N E C T Y S
T I M E D I S P L A Y
Setting
Data
Data
No.
Title