Electra Elite IPK Document Revision 4
Programming Manual 2 - 169
___________________________________________________________________________________
___________________________________________________________________________________
1-4-15 Automated Attendant Message Access
Code (2-Digit) Assignment
General Description
Use this Memory Block to specify a 2-digit code to route an incoming call from the
Automated Attendant.
Display
Related Programming
Refer to individual features in the Electra Elite IPK Features and Specifications Manual.
Notes
Programming Procedures
1 Go off-line.
2 Press LK1 + LK4 +
JJAE
to access the Memory Block.
3 Use the dial pad to enter Function Code for MSG. 1, Dial No. 00.
Use the following to enter data:
K
~
H
to enter Automated Attendant message number
KK
~
II
to enter Dial No.
4 Press G to write the data and to advance the Dial No.
5 Repeat Steps 3 and 4 for each Dial No. Message 2, Dial No. 00 is displayed.
6 Continue this cycle until the Dial number function codes are assigned to all AA MSGs. The next Memory Block is displayed.
7 Program the next Memory Block or press
E to go back on-line.
To use default 52~54, ringing must be assigned in Memory Blocks 4-01 [CO/PBX Ring Assignment (Day Mode)]
or 4-02 [CO/PBX Ring Assignment (Night Mode)].
System Mode
1
Submode
4
Data No.
15
PC Programming
¦
+AU
1 5 : A A A C 1 – 0 O = 0 3 0
T I M E D I S P L A Y
Data
No.
AA MSG.
(1~8)
Title
Function
Code
Dial.
No.
00~99
Default Values
Dial No. Funct. Code Contents
00 ~ 50 030 Specified Station Call (0)
51 011
Bypass Automated
Attendant
52 015 Paging Zone A Call
53 016 Paging Zone B Call
54 017 Paging Zone C Call
55 ~ 99 000 Not Used