1-16-11 Mirroring Source Port Assignment
General Description
When Port Mirroring is enabled in Memory Block 1-16-10 (Port Mirroring Selection),
use this Memory Block to specify a port with data to be monitored on another port
specified by Memory Block 1-16-12 (Mirroring Target Port Assigment) for each
HUB(8) -U( ) ETU. The source port and target port must be in the same VLAN(s).
R1500 or higher is required.
Display
Programming Procedures
1 Go off-line.
2 Press LK1 + LK16 +
JJAA
to access the Memory Block.
3 Use dial pad keys to enter Setting Data.
Use the following to enter data:
Use
J
to move cursor left
Use
L
to move cursor right
Use
K
~
I
to enter numeric data
Port range is 1~8.
Default Values
:
Port 1
4 Press G to write the data.
5 Repeat steps 3 and 4 for each HUB(8)-U( ) ETU.
6 Press
E to go back on-line.
System Mode
1
Submode
16
Data No.
11
PC Programming
¦
+AB
1 1 : 1 S O U R C E = 1
T I M E D I S P L A Y
Data
No.
Setting
Data