4-51 Off-Hook Ringing Selection
General Description
Use this Memory Block to assign per station Off-Hook Ringing to the Multiline
Te rminal.
Display
Settings
Notes
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8 The shaded
selection is the
default.
YS NO
Programming Procedures
1 Go off-line.
2 Press LK4 +
EA
to access the Memory Block.
3 Press LK2 to disable Off-Hook Ringing for Tel Port No.
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
~
I
to enter numeric data or Tel Port No.
– OR –
D to go to next assigned Tel Port No.
B +
A
to enter A for Port Numbers 100~109
B +
B
to enter B for Port Numbers 110~119
B +
C
to enter C for Port Number 120
Default Values
All Terminals = YS
4 Press G to write the data and display the next Memory Block.
5 Program the next Memory Block or press
E to go back on-line.
Telephone ports A0~C0 are ports 100~120.
Telephone Mode
4
Submode
—
Data No.
51
PC Programming
¦
+BTM
0 1 / 5 1 : O F F R I N G Y S
T I M E D I S P L A Y
Data
No.
Title
Tel
Port
No.
(01
~
C0)
Setting
Data
Title