Electra Elite IPK Document Revision 4
Programming Manual 2 - 183
___________________________________________________________________________________
___________________________________________________________________________________
1-6-01 Attendant Add-On Console to
Telephone Port Assignment
General Description
Use this Memory Block to assign an Attendant Add-On Console to a telephone port
number.
Display
Notes
Programming Procedures
1 Go off-line.
2 Press LK1 +
LK6 to access this Memory Block.
3 Use the dial pad to enter the data.
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
~
I
to enter numeric data
4 Press
G to write the data and advance to the next DSS No.
5 Repeat Steps 3 and 4 for each DSS. The next Memory Block is displayed.
6 Program the next Memory Block or press
E to go back on-line.
Related Programming
M.B. Number Memory Block Name
7-2
Telephone Type Assignment
1. The telephone with an Attendant Add-On Console connected must be specified by port number.
2. A maximum of four Attendant Add-On Consoles can be connected to a system.
3. A maximum of four Attendant Add-On Consoles can be connected to one telephone.
System Mode
1
Submode
6
Data No.
01
PC Programming
¦
+BTD
0 1 : D S S 1 = P 0 1
T I M E D I S P L A Y
Title
Data
Setting
Data
No.
DSS No.
1~4
Default Values
DSS Tel Port No.
1› 01
2› 02
3› 01
4› 02