Electra Elite IPK Document Revision 4
Programming Manual 2 - 495
___________________________________________________________________________________
___________________________________________________________________________________
3-73 CO Message Waiting Yes/No Selection
General Description
Use this Memory Block to specify whether or not the CO Message Waiting feature is
allowed per CO/PBX Line.
R2000 or higher is required.
Display
Settings
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8 The shaded
selection is the
default.
NO YES
Programming Procedures
1 Go off-line.
2 Press LK3 +
G +
GC
to access the Memory Block.
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
~
I
to enter numeric data or CO/PBX No.
– OR –
D to go to the next assigned CO/PBX No.
Default Values
CO/PBX No. 01~64 = NO
3 Press the corresponding CO/PBX line key to change the Setting Data option.
4 Press
G to write the selected data and display Memory Block 3-00 CO/PBX 02. After the last CO/PBX is programmed,
CO/PBX 01 is displayed again.
Related Programming
M.B. Number Memory Block Name
1-8-07
Class of Service (Attendant) Feature Selection 1
Page 3, LK 2
4-69
CO Message Waiting Indication Assignment
CO/PBX Line Mod