EasyManua.ls Logo

NEC Electra Elite IPK - Tie Line Length of Wink Signal Selection

NEC Electra Elite IPK
803 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 - 448 Memory Blocks
___________________________________________________________________________________
Document Revision 4 Electra Elite IPK
___________________________________________________________________________________
3-21 Tie Line Length of Wink Signal
Selection
General Description
Use this Memory Block to specify the time a wink pulse is sent to another system.
Display
Settings
Page 1
LK 1LK 2LK 3LK 4LK 5LK 6LK 7LK 8
The shaded
selection is the
default. Times
are in
milliseconds.
30 60 90 120 150 180 210 240
Page 2
LK 1LK 2LK 3LK 4LK 5LK 6LK 7LK 8
270 300 330 360 390 420 450 480
Programming Procedures
1 Go off-line.
2 Press LK3 +
G +
BA
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change wink-signal time for CO/PBX No.
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
~
I
to enter numeric data or CO/PBX No.
OR –
D to go to the next assigned CO/PBX No.
C to go to the next page
A to go to the previous page
4 Press
G to write the data and display the next Memory Block.
CO/PBX Line Mod
e
3
Submode
Data No.
21
PC Programming
¦
+ALM
0 1 / 2 1 : W I N K 1 8 0 | 1
T I M E D I S P L A Y
CO/PBX
No.
(01~64)
Data
No.
Title
Page
Setting
Data
Wink Pulse Sending
Incoming Signal Detection
Time
DC Loop Supervision
Receiving Side

Table of Contents

Other manuals for NEC Electra Elite IPK

Related product manuals