Electra Elite IPK Document Revision 4
Programming Manual 2 - 289
___________________________________________________________________________________
___________________________________________________________________________________
1-11-00 T1 Signal Format Selection
General Description
Use this Memory Block to specify the signal format of the T1 trunk connected to the
system. The signal format used (12- or 24-Multiframe) depends on the channel service
unit/demarcation (CSU/D mark) equipment being used.
Display
Settings
Notes
LK 1 LK 2LK 3LK 4LK 5LK 6LK 7LK 8
The shaded
selection is the
default.
12
(SF)
24
(ESF)
Programming Procedures
1 Go off-line.
2 Press LK1 + LK11
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option.
Setting Data:
SF = Superframe Format (12-Multiframe)
ESF = Extended Superframe Format (24-Multiframe)
4 Press
G to write the data. The next Memory Block is displayed.
5 Program the next Memory Block or press
E to go back on-line.
Related Programming
M.B. Number Memory Block Name
7-1
Card Interface Slot Assignment
The DTI-U( ) ETU must be assigned in the system to set this Memory Block.
System Mode
1
Submode
11
Data No.
00
PC Programming
¦
+AD
0 1 / 0 0 : F R A M E = 2 4
T I M E D I S P L A Y
0 1 / 0 0 : F R A M E = 2 4
T I M E D I S P L A Y
Data
No.
Setting
Data
DTI No.
(01~08)
Title