2 - 246 Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4 Electra Elite IPK
1-8-37 General Purpose Relay Assignment
General Description
Use this Memory Block to specify whether or not the General Purpose Relays on the
ECR-U( ) ETU are used.
Display
Settings
Notes
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8 The shaded
selection is the
default.
NO YS
Programming Procedures
1 Go off-line.
2 Press LK1 + LK8 +
CG
to access the Memory Block.
3
Press the corresponding CO/PBX line key to specify whether or not relay 0 is used
.
Default Values
NO
4 Press G to write the data and advance to relay 1.
5 Press
G to write the data for relay 1. The next Memory Block is displayed.
6 Program next Memory Block or press
E to go back on-line.
Related Programming
M.B. Number Memory Block Name
1-6-05
Attendant Add-On Console Key Selection
These General Purpose Relays are normally open relays.
System Mode
1
Submode
8
Data No.
37
PC Programming
¦
+BP
3 7 : R E L A Y ( 0 ) = N O
T I M E D I S P L A Y
Data
No.
Setting
Data
Title
Relay