1-4-19 Automated Attendant 1
st
to 2
nd
Delay
Announcement Interval Time
Selection
General Description
Use this Memory Block to specify the time, in seconds or minutes, between the
Automated Attendant Delay Announcement messages.
Display
Settings
Page 1
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8
The shaded
selection is the
default.
0s 10s 20s 30s 1m 2m 3m 4m
Page 2
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8
5m 10m 20m
Programming Procedures
1 Go off-line.
2 Press LK1 + LK4 +
JJAI
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the interval time.
Example: To change 4 minutes to 10 seconds, press CO/PBX LK2.
Press C to toggle between pages.
Default Values
4 minutes
4 Press G to write the data and advance to the next Memory Block.
5 Program the next Memory Block or press
E to go back on-line.
Related Programming
M.B. Number Memory Block Name
1-4-18
Automated Attendant Delay Announcement Assignment
1-4-20
Automated Attendant Delay Announcement Disconnect Time Selection
System Mode
1
Submode
4
Data No.
19
PC Programming
¦
+ AU
1 9 : 1 S T I N T R 4 m | 1
T I M E D I S P L A Y
Setting
Data
Data
No.
Title
Page