2 - 446 Memory Blocks
___________________________________________________________________________________
Document Revision 4 Electra Elite IPK
___________________________________________________________________________________
3-20 Tie Line Loop Off-Guard Time
Selection
General Description
Use this Memory Block to assign loop off-guard time to prevent noise that could cause
the system to be unable to answer an incoming Tie line.
Display
Settings
Page 1
LK 1LK 2LK 3LK 4LK 5LK 6LK 7LK 8
The shaded
selection is the
default. Times
are in seconds.
0.0 0.5 1.0 1.5 2.0 3.0 4.0. 5.0
Page 2
LK 1LK 2LK 3LK 4LK 5LK 6LK 7LK 8
6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0
Programming Procedures
1 Go off-line.
2 Press LK3 +
G +
BK
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change loop off-guard time for CO/PBX No.
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
~
I
to enter numeric data or CO/PBX No.
– OR
D to go to the next assigned CO/PBX No.
C to go to the next page
A to go to the previous page
4 Press
G to write the data and display the next Memory Block.
5 Program the next Memory Block or press
E to go back on-line.
CO/PBX Line Mod
e
3
Submode
Data No.
20
PC Programming
¦
+ALM
0 1 / 2 0 : L O O P 2 . 0 | 1
T I M E D I S P L A Y
CO/PBX
No.
(01~64)
Data
No.
Title
Page
No.
Setting
Data

Table of Contents