Electra Elite IPK Document Revision 4
Programming Manual 3 - 51
___________________________________________________________________________________
___________________________________________________________________________________
3.9 Call by Call (CBC) Termination Flowchart
The flowchart shows how Call by Call incoming calls are terminated.
Incoming
Incoming Reject
#88: Incompatible
Destination
Call Type
SFG
MB 1-10-01~08
CBC?
MB 1-13-03
Voice
Others
CBC Call Termination Flowchart
Yes
No
Trunk Type
MB 3-91
Called Party
Number
(CPN)?
DID
Incoming Type
MB 1-10-22
Data Match
No Match
DID
DIT/ANA
Assigned?
MB 3-42,3-43
No
Software selects
SFG 16
Yes
Digit Add/Del for Tie Line
Networking (MB 5-00)
Normal Incoming, A.A., Auto
Trunk-to-Trunk Transfer
DID/DIT (also Call Alert)
Digit Conversion Table
MB 1-1-22
No
CO
Yes
CO