Electra Elite IPK Document Revision 4
Programming Manual 2 - 487
___________________________________________________________________________________
___________________________________________________________________________________
3-65 Hold Tone Automated Attendant
Selection
General Description
Use this Memory Block to specify the Automated Attendant message that is played to
an extension or DID trunk on an incoming call.
Display
Settings
Page 1
LK 1LK 2LK 3LK 4LK 5LK 6LK 7LK 8
The shaded
selection is the
default.
NONEMSG 1MSG 2MSG 3MSG 4MSG 5MSG 6MSG 7
Page 2
LK 1LK 2LK 3LK 4LK 5LK 6LK 7LK 8
MSG 8
Programming Procedures
1 Go off-line.
2 Press LK3 +
G +
FE
to access the Memory Block.
3 Press line key to specify the Automated Attendant message to play to an extension or DID trunk on an incoming call to CO/PBX
No.
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
~
I
to enter numeric data or CO/PBX No.
– OR –
D to go to the next assigned CO/PBX No.
C to go to the next page
A to go to the previous page
4 Press
G to write the selected data and display the next Memory Block.
5 Program the next Memory Block or press
E to go back on-line.
CO/PBX Line Mod
e
3
Submode
Data No.
65
PC Programming
¦
+AU
0 1 / 6 5 : I N C N O N E | 1
T I M E D I S P L A Y
CO/PBX
No.
(01~64)
Data
No.
Title