2 - 198 Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4 Electra Elite IPK
1-7-05 Doorphone Ringing Frequency
Selection
General Description
Use this Memory Block to specify the doorphone ringing frequency. Doorphones can
be individually assigned.
Display
Settings
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8 The shaded
selection is the
default.
AB C D E F G H
Programming Procedures
1 Go off-line.
2 Press LK1 + LK7+
KE
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option.
The available tones are:
4 Press
G to write the data.
5 Repeat Steps 3 and 4 for each of the four doorphones. The next Memory Block is displayed.
6 Program the next Memory Block or press
E to go back on-line.
System Mode
1
Submode
7
Data No.
05
PC Programming
¦
+BTP
0 5 : D P H 1 F R E Q C
T I M E D I S P L A Y
Setting
Data
Title
Data
No.
Tone Frequency
Tone A 480/600 (Modulation - 16 Hz)
Tone B 480/606 (Modulation - 8 Hz)
Tone C 1024/1285
Tone D 1024
Tone E 500
Tone F 1024/1285 (Modulation - 16 Hz)
Tone G 600/700 (Modulation - 16 Hz)
Tone H 1024 (Envelope - 2 sec.)