Electra Elite IPK Document Revision 4
Programming Manual 2 - 21
___________________________________________________________________________________
___________________________________________________________________________________
1-1-13 CO Transfer Ring Pattern Selection
General Description
Use this Memory Block to select a Ring Pattern for CO transfers.
Display
Settings
(Page 1)
LK 1LK 2LK 3LK 4LK 5 LK 6 LK 7 LK 8
The shaded
selection is the
default.
OFF ON A B C D E F
(Page 2)
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8
G H
Programming Procedures
1 Go off-line.
2 Press LK1 +
LK1 +
AC
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option.
Use the following to enter data:
C to access the next page
A to access the previous page
4 Press
G to write the data and display the next Memory Block.
5 Program the next Memory Block or press
E to go back on-line.
Related Programming
M.B. Number Memory Block Name
1-1-11
System Transfer/Camp-On Selection
1-1-14
CO Transfer Ring Tone Selection
System Mode
1
Submode
1
Data No.
13
PC Programming
¦
+BCS
1 3 : C O T P T N C | 1
T I M E D I S P L A Y
Setting
Data
Title
Data
No.
Page